EQUIPPED WITH:
Totally Enclosed Cabinet
440 Volt 3/60 AC Power
10.13 Amps
Last used with 40% Glyco Water
Electrical Diagrams
6.8 Amp Compressor
2hp, 1750 rpm Pump Motor & Condensor Motor
Copeland Model F3AD-A20 Condesing Unit
Fan Motors
Tank w/Leveling Gauge
SPECIFICATIONS:
Capacity:1.7 Ton
Length: 50"
Width: 29"
Height:81 1/2"
OPERATING SEQUENCE:
Start push button will energize im coil and the pump motor will run a cooling
cycle and on light will be lit.
With "ITT" contacts closed from 6-7 due to need for cooling "ICON" coil will
be energized and fan motors and compressor motor will operate.
When need for cooling is satisfied "ITT" contacts will open "ICON" coil will
de-energize when need for cooling occures again "ITT" contacts will close and
"ICON" coil will re-energize this will cycle fan motors and compressor motor
as required.
Note: Units are in very good condition. Price at less than 25% of replacement
cost.